Elsist UPS NemoLED 120 1200VA/480W, Line-Interactive, 2×Schuko, 1×9Ah, 10min. autonomija
1200VA/480W, Line-Interactive, 2×Schuko, 1×9Ah, 10min. autonomija
Full power protection.
- Electrical noise suppression, voltage and overvoltage peak suppression, autonomy, are common requirements to many UPS types. This UPs provides a wider voltage range capability, in addition to the aforementioned characteristics. Within this wide voltage range, the load is supplied without any support from the battery.
This feature not only protects your computer, but also improvand increases battery lifetime.
Cold start function (DC Start).
- All NEMOLCD models are equipped with cold start function, which means that even if the power supply is unplugged, the UPS can be activated simply by pushing the ON / OFF switch and will operated supplied by the battery.
Autorestart.
- Upon returning the Mains, the UPS will restart automatically.
Overload protection.
- The internal microprocessor controls the load status in any operating conditions. In the event of overload or short circuit, your UPS will beep or will automatically turn off to avoid undesired damage to the load.
- All controls are performed and guaranteed by a high reliability microprocessor.
- “Green Power” function for energy saving.
- Light weight and compact dimensions.
Specifications
INPUT
- Input Voltage: 220-230-240Vac
- Input voltage range: 162-290Vac
- Frequency: 50/60Hz (auto selection)
OUTPUT
- Output Voltage: 230Vca
- Wave type: Simulated sine wave
- Output voltage range: + - 10%
- Frequency: 50/60Hz (following input frequency)
- Power (VA/W): 1200VA/480W
- Switching time: 2-6 mS tpc, 10ms max
- Schuko outlet: 2
NOISE FILTERING
- Yes
BATTERY
- Typ. Autonomy time: 10 min
- Battery Voltage: 1x 12V/9Ah
- Type: Maintenance-free, sealed lead-acid
- Overload/Shortcircuit: Electronic limit (both on “Mains mode” and on “Battery Mode”)
PROTECTION
- Overvoltage/Undervoltage: Switch to “Battery mode”
- Overload/Shortcircuit: Fuse and Electronic threshold (both on “Mains mode” and on “Battery mode”).
AUDIBLE ALARM
- Battery mode: 1 time every 10 sec
- Battery low: 1 time per sec
- Overload: 1 time every 0,5 sec
- Fault: continuosly
MECHANICAL CHARACTERISTICS
- Dimensions (WxDxH) mm: 101x282x142
- Weight (Kg): 4,3
ENVIROMENT
- Ambient Temperature: 0-40°C ,Humidity 0-90% without condensa tion, altitude max. 3000 mt.
- Audible noise: < 40dbA (measured at 1mt.) both on “Mains mode” and on “Battery mode”.
STANDARD
- IEC/EN62040-1, IEC/EN62040-2, IEC/EN62040-3, IEC/EN60950-1